Load Cell Excitation: |
10VDC, Fixed,
Short-Circuit Proof |
Load Cell Current: |
240 mA max (8)
350W Load Cells |
Load Cell Cabling: |
4 Wire
standard, 6 Wire with PC trace cuts |
Analog Signal Input: |
0.7 mV/V - 2.0
mV/V ("Hi Span") |
Analog Sensitivity |
0.3µV/grad
max |
Transient
Overload: |
±
100 VDC without damage -100 uS duration at 2% duty cycle |
Update Rate: |
10
update/second, no averaging |
Integration
Time: |
20
mSec. typ |
Display
Resolution: |
10,000
Displayed Grads
100,000 Internal Grads |
Display
Increments: |
1-2-5-10-20-50-100 |
Full Scale
Capacity: |
Selectable:
500 |
2500 |
6000 |
1000 |
3000 |
8000 |
1500 |
4000 |
10000 |
2000 |
5000 |
|
|
Display
Blanking: |
Overload
blanking occurs at 103% of Full Scale Capacity |
Under Range
Blanking: |
(-)
400 Displayed Grads, typ |
Lead Zero
Blanking: |
Standard,
per NBS H-44 Requirements |
Display: |
Six
(6) Decades, 0.6" LED digits |
Polarity
Indication: |
"-"
Sign |
Decimal Point: |
Selectable
to: 0 - 0.0 - 0.00 - 0.000 - 0.0000 or 0.00000 |
lb/kg
Conversion: |
Via
Front Panel Dip Switch, with Conversion for Weight, Tare Values |
Front Panel
Keys: |
ZERO,
GROSS/NET, TARE, PRINT |
Display
Annunciators: |
Center
Zero, Net, lb, kg, Motion (Red Spot LED's) |
AZM (Zero
Track): |
Gross
mode only |
AZM Capture
Band: |
Selectable
to "off", ± 0.5 ± 1.0, ± 3.0 grads |
AZM Aperture: |
Selectable
to ± 1.9% Full Scale or 100% Full Scale |
Motion Band: |
Selectable
or "off" ± 1 or ± 3 displayed grads, 1 sec delay |
Power Input: |
117/237
VAC, 50-60 Hz, or External DC |
Display Check: |
All
digit segments and annunciators sequentially illuminated upon power
application |
Serial Output: |
Standard
Simplex 20 mA Current Loop |
Enclosure: |
Mild
Steel, NEMA 1 General Purpose. Tilt - Stand Base Standard |
Options: |
| Duplex Serial RS232/20
mA
| Rack Panel Mount Kit
| Isolated Analog 4-20
mA or 0-10V output
| BCD output
| Load Cell Connector |
| | | |
|