Farm/
Cattle/
Horse Livestock
Scales
Paul
Livestock
Scales
Portable
Truck Scales
A&D Scales
Click
here for
A&D
balances
Click
here for
A&D
scales
Transcell
Technology
Scales / load cells
Avery
Berkel
Scales
Money Scales
Label
Printing Scales
from $995
Products
Pallet_Scales
Legal
for Trade scales
Used
Scales
Lab
Balances
Bench Scales
Stainless Bench Scales
Stainless
Checkweighers
Stainless
Portion Scales
Counting
Scales
Crane Scales
Floor
/ Drum Scales
Fork Lift
Scales
Indicators
Junction Boxes
Livestock
Scales
Load Cells
Mechanical
Scales
Money Counting
Scales
Postal Scales
Price
Computing/Deli
Printers
Remote
Displays
Shipping
Scales
Truck Scales
Health/Physician/Baby
| |
COMMUNICATION
FEATURES
RS232, 20ma current loop, RS485, are all
standard serial interfaces. Even, odd, or no parity, 7 or 8 data bits, and baud
rates 300 through 9600 baud are all selectable. One EPROM fits all continuous
or demand mode applications. Pulse inputs up to 48V DC are standard for
conveyor scale applications. TTL level remote print inputs are also
standard. BCD interface is an available option.
PRINT
FEATURES
BI-DIRECTIONAL
PRINT
The printer normally prints BI-directionally for
faster operation.
MULTI-STRIKE PRINT
Multi-strike
will print each line from 2 to 10 times. Legibility is increased in multi-copy
tickets. The multistrike feature prints in a single direction. When selected, it
will over-ride the BI-direction select.
LEFT MARGIN
Left margin is used to move printed text to the right 1 to 18 characters wide.
If invert print is used , the text will be moved to the left.
TOP MARGIN
Top margin is
used to skip from 1 to 9 lines down the ticket before printing.
INVERT PRINT
Characters are
printed upside down, the ticket is inserted upside down for printing. This
feature is used to print on the left side of documents wider than the width of
40 characters.
AUTOMATIC
PAPER RELEASE
In some applications, the sending device does not send a
paper release command. This feature releases the document after printing the
last line received.
AUTOMATIC
PRINT WRAP
If more than 40 characters (20 Enhanced) are sent without
a linefeed command, overflow data is automatically printed on the next line and
not lost.
AUTOMATIC LINE FEED
This feature is used when the host device (weight meter
etc.) does not send a line feed command after carriage return.
INHIBIT PRINT
IF PAPER EMPTY
The printer will not print if the paper is not in place. A
"Form " or "Paper" indicator on the front panel indicates
paper error.
TIME AND DATE
PRINT FORMAT
Time and date can be disabled or printed in six different
formats and at 3 different locations.
STATION
NUMBERING
Numbers 1 through 9 can be printed in a multiple station
application to differentiate between them.
PRINT SIZES:
(Normal, Enhanced, or Mixed)
The normal is 12 char/inches (Typewriter size). Enhanced
print is double width (6 char/inch). Mixed prints text normal size and numbers
enhanced.
TRANSACTION
NUMBERING
Up to 10
digits of sequential transaction (ticket) numbering is automatically printed on
each transaction. Numbers 5 digit long can be reset, over 5 digits cannot. Use 6
digits up to eliminate pilferage.
HEADER LABEL
Up to 30 characters of company name or other information can be printed on each
ticket transaction.
OPERATING
MODES
MODE 0
The basic (slave) printer mode prints what is sent. The print switch requests
data transmission from the host. The aux switch releases paper.
MODE 1
Prints the weight on the scale in the form:
WEIGHT
2345LB
MODE 2
Prints weight on the scale with gross, and tare labels. Depress print switch to
print GROSS, and depress aux switch to print TARE.
GROSS
29687LB
TARE
1977LB
MODE 3
Provides gross, tare and net printing in two weighments. The aux switch stores
tare weight. The print switch causes the printer to print gross, tare, and net
weights.
GROSS
3966LB
TARE
1970LB
NET
1996LB
MODE 4
Provides a totalize register for summing weighments. The print switch prints the
weight and adds it to the total register. The aux switch prints the total. Press
the aux switch twice within 10 seconds to clear the total register.
WEIGHT
6962LB
WEIGHT
6962LB
TOTAL
13924LB
TOTAL CLEARED
MODE 5
Provide a subtotal and total register. The print switch prints the weight on the
scale and adds it to the total and subtotal registers. The aux switch prints and
clears the subtotal registers. Press aux again to print the total. Press aux
twice within 10 seconds to clear the total register.
WEIGHT
966LB
WEIGHT 1964LB
SUBTOT 2930LB
TOTAL 10788LB
MODE 6
This mode is used for sequentially numbering and totalizing weighments. The
print switch prints a sequence number and weight. The aux switch prints the
total.
# 1
1964LB
# 2
2962LB
# 3
3962LB
TOTAL 10788LB
MODE 7
Allows the weigh-in of a truck, container, etc. either empty or full, and
weigh-out after filling or unloading. Print and aux switches operate like Mode
3.
WEIGH-IN 3962LB
WEIGH-OUT 2962LB
NET WEIGHT 1000LB
SPECIFICATIONS
GENERAL
SPEC.
Power:
120 VAC ±10%, 50/60 Hz, or 240 VAC ±10%,
50/60Hz.
Power Consumption
operating:
90 watts.
Environmental:
32 F to 115 F (0 C to 46 C), to 80% non-condensing relative humidity.
Size:
12" wide, 9" deep, and 8 ¼" high (30.5 x 22.5 x 21.0 cm).
Weight:
18 lbs (8.1 kg).
Enclosure
Construction:
16 ga. Cold Rolled Steel Sheet Metal.
PRINTING
SPEC.
Type:
5 X 7 dot matrix, serial impact.
Character Size:
0.12 high, 0.07 wide (3.1mm x 1.8mm) [0.14 wide (3.6mm) when enhanced.
Line Spacing:
6 lines per inch (4.23mm).
Pitch:
12 characters per inch (2.12mm).
Print
Speed:
3 Lines per second.
HARDWARE
A
4k input buffer insures data from the transmitting device is not lost
while the printer is printing. A Ni-Cad battery and charging circuit
protect the transaction number, time and date, and totals form being lost for up
to 2 weeks without power. All other information such as the header labels etc is
stored in earom so it will never be lost even if the battery fails.
Costly repairs are eliminated by fusing each individual dot head solenoid to
insure against damage
| |
Sensortronics
load cells
Scaime
load
cells
Revere
Transducer
Load cells
BLH
load cells
Wheelchair Scales
Click below to
Translate our website into Spanish, Chinese, French, German, Italian, Japanese,
Korean or Portuguese.
Click